MiroxMirox
  • Platform

    • Philosophy
    • Platform Overview
    • Platform Resources
    • Availability and Maintenance Windows
    • Releases and Versions
  • Mirox-Cloud

    • Cloud Overview
    • Connected Microservices
  • Mirox-Agent

    • Agent Overview
    • Deployment Options
    • Data Scraper
    • Digital Twin
  • Technical Details

    • Metric Collection
  • Information

    • Supported Plants
  • Plant Types

    • Solar Plants
    • Solar Trackers and Park Controllers
    • Transformer Stations
    • Wind Plants
    • Battery Storage
    • Alarm System
  • Monitoring & Visualization

    • Real-time Monitoring
    • Digital Twin
    • Component States
    • Inverter Status Codes
    • Inverter Events
    • Loss Detection
    • Power Limits & Curtailment
    • Efficiency Detection
    • KPI Dashboard
  • Data Management

    • Events
    • Alarm Levels
    • Tickets
    • Forecasts
    • Reports
    • Metrics
  • Alert Manager

    • Overview
    • Alert Rules
    • Alerts & Notifications
    • Examples
  • Integration & Sharing

    • Cooperations
    • API Tokens
    • VPN
    • VPN Address Conflicts
    • Proxy
  • AI

    • AI Assistant & Wizards
    • Agentic Access (MCP)
  • Billing

    • Market & Tariffs
    • How Revenue Is Calculated
    • Accounting & Billing
    • Contracts
    • Service Certificates & Invoices
  • Collaboration

    • Invitations
  • Security

    • Authentication
    • Account Lockout
    • Organization Security Policy
    • Permission System
    • Network Segmentation
    • Cooperation Restrictions
    • Access Audit Logging
    • Activity & Audit Trail
    • Data Isolation
  • Getting Started

    • Onboarding
    • Setup
  • Personal

    • Using the VPN
    • Using the Proxy
    • Two-Factor Authentication
    • Sessions
    • API Tokens
    • Notifications
    • Connect Microsoft Teams
  • Per Park

    • Contacts
    • Network Devices
    • Data Loggers
    • Generic Modbus Reader
    • Components
    • Direct VPN (per Agent)
    • Data Volume
    • History Import
  • Organization

    • Member Permissions
    • Security Policy
    • Cooperations
    • File Storage
    • VPN Services
    • Working with Reports
  • Data Export

    • Metric Export
    • Metric Export API
    • Migrating to the Metric Export
    • Legacy Export API
    • External Report Generation
    • Grafana
    • Grafana Dashboards
    • API Overview
    • MiroxQL Formulas (API)
  • Support

    • Request an Integration
  • Reporting

    • External Report Generator
    • Metric Export for Excel
  • Remote Access
  • Account Security
  • AI in Mirox
  • History Import
  • Reports
  • Data Export
  • English
  • Deutsch
  • Español
  • Français
  • Português
  • Italiano
  • English
  • Platform

    • Philosophy
    • Platform Overview
    • Platform Resources
    • Availability and Maintenance Windows
    • Releases and Versions
  • Mirox-Cloud

    • Cloud Overview
    • Connected Microservices
  • Mirox-Agent

    • Agent Overview
    • Deployment Options
    • Data Scraper
    • Digital Twin
  • Technical Details

    • Metric Collection
  • Information

    • Supported Plants
  • Plant Types

    • Solar Plants
    • Solar Trackers and Park Controllers
    • Transformer Stations
    • Wind Plants
    • Battery Storage
    • Alarm System
  • Monitoring & Visualization

    • Real-time Monitoring
    • Digital Twin
    • Component States
    • Inverter Status Codes
    • Inverter Events
    • Loss Detection
    • Power Limits & Curtailment
    • Efficiency Detection
    • KPI Dashboard
  • Data Management

    • Events
    • Alarm Levels
    • Tickets
    • Forecasts
    • Reports
    • Metrics
  • Alert Manager

    • Overview
    • Alert Rules
    • Alerts & Notifications
    • Examples
  • Integration & Sharing

    • Cooperations
    • API Tokens
    • VPN
    • VPN Address Conflicts
    • Proxy
  • AI

    • AI Assistant & Wizards
    • Agentic Access (MCP)
  • Billing

    • Market & Tariffs
    • How Revenue Is Calculated
    • Accounting & Billing
    • Contracts
    • Service Certificates & Invoices
  • Collaboration

    • Invitations
  • Security

    • Authentication
    • Account Lockout
    • Organization Security Policy
    • Permission System
    • Network Segmentation
    • Cooperation Restrictions
    • Access Audit Logging
    • Activity & Audit Trail
    • Data Isolation
  • Getting Started

    • Onboarding
    • Setup
  • Personal

    • Using the VPN
    • Using the Proxy
    • Two-Factor Authentication
    • Sessions
    • API Tokens
    • Notifications
    • Connect Microsoft Teams
  • Per Park

    • Contacts
    • Network Devices
    • Data Loggers
    • Generic Modbus Reader
    • Components
    • Direct VPN (per Agent)
    • Data Volume
    • History Import
  • Organization

    • Member Permissions
    • Security Policy
    • Cooperations
    • File Storage
    • VPN Services
    • Working with Reports
  • Data Export

    • Metric Export
    • Metric Export API
    • Migrating to the Metric Export
    • Legacy Export API
    • External Report Generation
    • Grafana
    • Grafana Dashboards
    • API Overview
    • MiroxQL Formulas (API)
  • Support

    • Request an Integration
  • Reporting

    • External Report Generator
    • Metric Export for Excel
  • Remote Access
  • Account Security
  • AI in Mirox
  • History Import
  • Reports
  • Data Export
  • English
  • Deutsch
  • Español
  • Français
  • Português
  • Italiano
  • English
  • Monitoring & Visualization

    • Real-Time Monitoring
    • Digital Twin
    • Component States
    • Inverter Status Codes
    • Inverter Events
    • Loss Detection
    • Power Limits and Curtailment
    • Efficiency Detection (PRRC)
    • Local Network Inspector
    • Access Monitoring
    • KPI Dashboard
    • Graph Visualization
  • Data Management

    • Events
    • Alarm Levels and Notifiable Events
    • Tickets
    • Forecasts
    • Reports
    • Metrics
  • Alert Manager

    • Alert Manager
    • Alert Rules
    • Alerts & Notifications
    • Examples
  • Integration & Sharing

    • Cooperations
    • API Tokens
    • VPN
    • VPN: Address Conflicts
    • Proxy (Web Access to Plant Devices)
  • AI

    • AI Assistant & Wizards
    • Agentic Access (MCP)
  • Billing

    • Market & Tariffs
    • How Revenue Is Calculated
    • Accounting & Billing
    • Contracts
    • Service Certificates & Invoices
  • Collaboration

    • Invitations
  • Security

    • Authentication
    • Account Temporarily Locked
    • Organization Security Policy
    • Permission System
    • Network Segmentation
    • Cooperation Permission Restrictions
    • Access Audit Logging
    • Activity & Audit Trail
    • Data Isolation

Examples

Each example lists the fields to set in the rule editor. Fields not mentioned keep their default. Most of them are also offered as system templates on the Rules tab: open one and Save as copy, or Adopt it in one step — it is created switched off, so you can review it before it fires. Before saving or switching on, use Replay on a plant to check the threshold against your own plants — the numbers below are starting points, not recommendations for every plant. The rule assistant builds any of these from a single sentence, too.

Turbine Not Operational → Outage Report to the Direct Marketer

A turbine that is faulted, stopped or unreachable for half an hour — around the clock — reported to the plant's direct marketer as an outage, continuously, until the turbine runs again. This is the first system template.

  • What it watches: Turbine availability per turbine — Each component
  • Value: Latest value · is below · Threshold 100 %
  • For at least: 25 min
  • Only during: nothing — always
  • Level: High
  • Alert text: {component}: turbine not operational for 25 minutes → outage report to the direct marketer
  • Report outages (Notification tab): on — reason Maintenance, remaining power Full stop (0 kW); your direct marketer's receiver is attached when you adopt the template — or your own email receiver first, to rehearse (see Direct marketer)

One alert opens per turbine that is not operational, and the plant reports the outage to its direct marketer two hours ahead the moment the alert opens. While the alert keeps firing, the report is renewed about every half of the hours ahead (every hour at the two-hour default), so the window never has a gap; when the turbine runs again, the report is cut back to the real end. Nothing else has to be configured — the plant only needs its direct marketer set up under Organization ▸ Direct marketers (which also creates the receiver) and linked on its Unavailability page; see Direct marketer. The 25-minute hold on the five-minute check means a 30-minute outage reaches the marketer and a short blip does not.

Two more templates attach the receivers the same way: Turbine down by a fault → outage report to the direct marketer watches the power a turbine loses to a fault for 15 minutes; Turbine curtailed for the environment → outage report to the direct marketer watches a curtailment for bats, birds, noise or shadow for 15 minutes — its outage reason is Administrative order; switch its remaining power to the measured value if the turbines keep delivering during the curtailment. A rule on the plant total — such as the share of units available — is never reported, whatever receivers it has.

Inverter Without Power During the Day

An inverter that delivers nothing for two hours while the sun is up.

  • What it watches: AC power per inverter — Each component
  • Value: Latest value · is below · Threshold 10 W
  • For at least: 120 min
  • Only during: Sunrise +1 h – sunset −1 h
  • Level: High
  • Alert text: {component} delivers only {value} (limit {threshold})

One alert opens per affected inverter and resolves when it produces again. Shorten the hours in winter, or use a metric of your own that compares with the irradiance — see the next example.

Plant Feeding In Too Little

The plant's yield falls far below what the weather allows.

  • What it watches: an organization metric such as performance ratio — Plant total
  • Value: Over the last 60 min · is below · Threshold 0.7
  • Clears only at: 0.8
  • Only during: Mon – Sun, sunrise +2 h – sunset −2 h
  • Level: Normal

The clear threshold keeps a ratio wavering around 0.7 from opening and closing the alert every few minutes.

Flapping String

A string that drops out again and again, even if each drop is short.

  • What it watches: string current — Each component
  • Value: Latest value · is below · Threshold 0.1 A
  • Fire when it happens several times: 3 times within 60 minutes
  • Only during: Sunrise +1 h – sunset −1 h
  • Level: Normal

Meter Stopped Reporting

The grid meter delivers no values, although the plant itself is still connected.

  • What it watches: grid feed-in — Plant total
  • Value: Latest value · is below · Threshold −1000000000 (never true by value)
  • When there is no value: Alert
  • For at least: 30 min
  • Level: High

The condition itself never holds, so only missing data opens the alert. If the whole plant stops reporting, the separate alert Alert rules not checked opens instead — see Engine status.

Battery Converter Not Operational

A battery converter that is faulted, tripped by a protection or unreachable for half an hour — around the clock.

  • What it watches: Converter availability per converter — Each component
  • Value: Latest value · is below · Threshold 100 %
  • For at least: 25 min
  • Level: High
  • Alert text: {component} not operational (availability {value})

A converter counts available while its operating state is at most stopped by command — a stop somebody ordered is a unit that would run. 25 minutes on the five-minute check means a 30-minute outage alerts and a shorter blip does not. The same rule on Inverter availability per inverter watches a solar park's inverters during daylight; on Turbine availability per turbine it is the first example, which additionally reports to the direct marketer.

More Than 20 % of the Plant's Units Unavailable

Too many of the plant's units — its turbines, battery converters or inverters — are out at once.

  • What it watches: Share of units available — Plant total
  • Value: Latest value · is below · Threshold 80 %
  • For at least: 25 min
  • Level: High
  • Alert text: Only {value} of the plant's units are available (limit {threshold})

The metric picks the plant's own units: the turbines of a wind park, the battery converters of a storage park or a plant with a battery, the inverters of a solar park (daylight only). Units unavailable gives the same thing as a plain count, so a rule can also say "more than two units are out". Being a plant total, this rule is never reported to the direct marketer — the per-turbine rule above is.

Maintenance Window

The inverters of one plant are replaced on Thursday — nobody should be woken up.

Create a silence for that plant and every rule, for one day, with the comment inverter replacement. Alerts are still recorded and marked Silenced; the dialog tells you how many open alerts the silence would hold right now, and after the silence, notifications resume by themselves. For a single alert that is already firing, Silence this alert in its details does the same for just that rule, plant and component.

Report to a Team Channel

The alerts of your most important rules go to the operations channel in Microsoft Teams.

Create a Webhook receiver with the format Microsoft Teams and the address of the channel's incoming webhook (how to create one), then attach it to the rules under Receivers on the Notification tab. A receiver gets every alert of its rules regardless of anybody's level settings — attach it only to the rules the channel should hear about.

Prev
Alerts & Notifications
© 2026 Mirox Verwaltungs GmbH. All rights reserved. | Privacy Policy