MiroxMirox
  • Platform

    • Philosophy
    • Platform Overview
    • Platform Resources
    • Availability and Maintenance Windows
    • Releases and Versions
  • Mirox-Cloud

    • Cloud Overview
    • Connected Microservices
  • Mirox-Agent

    • Agent Overview
    • Deployment Options
    • Data Scraper
    • Digital Twin
  • Technical Details

    • Metric Collection
  • Information

    • Supported Plants
  • Plant Types

    • Solar Plants
    • Solar Trackers and Park Controllers
    • Transformer Stations
    • Wind Plants
    • Battery Storage
    • Alarm System
  • Monitoring & Visualization

    • Real-time Monitoring
    • Digital Twin
    • Component States
    • Inverter Status Codes
    • Inverter Events
    • Loss Detection
    • Power Limits & Curtailment
    • Efficiency Detection
    • KPI Dashboard
  • Data Management

    • Events
    • Alarm Levels
    • Tickets
    • Forecasts
    • Reports
    • Metrics
  • Alert Manager

    • Overview
    • Alert Rules
    • Alerts & Notifications
    • Examples
  • Integration & Sharing

    • Cooperations
    • API Tokens
    • VPN
    • VPN Address Conflicts
    • Proxy
  • AI

    • AI Assistant & Wizards
    • Agentic Access (MCP)
  • Billing

    • Market & Tariffs
    • How Revenue Is Calculated
    • Accounting & Billing
    • Contracts
    • Service Certificates & Invoices
  • Collaboration

    • Invitations
  • Security

    • Authentication
    • Account Lockout
    • Organization Security Policy
    • Permission System
    • Network Segmentation
    • Cooperation Restrictions
    • Access Audit Logging
    • Activity & Audit Trail
    • Data Isolation
  • Getting Started

    • Onboarding
    • Setup
  • Personal

    • Using the VPN
    • Using the Proxy
    • Two-Factor Authentication
    • Sessions
    • API Tokens
    • Notifications
    • Connect Microsoft Teams
  • Per Park

    • Contacts
    • Network Devices
    • Data Loggers
    • Generic Modbus Reader
    • Components
    • Direct VPN (per Agent)
    • Data Volume
    • History Import
  • Organization

    • Member Permissions
    • Security Policy
    • Cooperations
    • File Storage
    • VPN Services
    • Working with Reports
  • Data Export

    • Metric Export
    • Metric Export API
    • Migrating to the Metric Export
    • Legacy Export API
    • External Report Generation
    • Grafana
    • Grafana Dashboards
    • API Overview
    • MiroxQL Formulas (API)
  • Support

    • Request an Integration
  • Reporting

    • External Report Generator
    • Metric Export for Excel
  • Remote Access
  • Account Security
  • AI in Mirox
  • History Import
  • Reports
  • Data Export
  • English
  • Deutsch
  • Español
  • Français
  • Português
  • Italiano
  • English
  • Platform

    • Philosophy
    • Platform Overview
    • Platform Resources
    • Availability and Maintenance Windows
    • Releases and Versions
  • Mirox-Cloud

    • Cloud Overview
    • Connected Microservices
  • Mirox-Agent

    • Agent Overview
    • Deployment Options
    • Data Scraper
    • Digital Twin
  • Technical Details

    • Metric Collection
  • Information

    • Supported Plants
  • Plant Types

    • Solar Plants
    • Solar Trackers and Park Controllers
    • Transformer Stations
    • Wind Plants
    • Battery Storage
    • Alarm System
  • Monitoring & Visualization

    • Real-time Monitoring
    • Digital Twin
    • Component States
    • Inverter Status Codes
    • Inverter Events
    • Loss Detection
    • Power Limits & Curtailment
    • Efficiency Detection
    • KPI Dashboard
  • Data Management

    • Events
    • Alarm Levels
    • Tickets
    • Forecasts
    • Reports
    • Metrics
  • Alert Manager

    • Overview
    • Alert Rules
    • Alerts & Notifications
    • Examples
  • Integration & Sharing

    • Cooperations
    • API Tokens
    • VPN
    • VPN Address Conflicts
    • Proxy
  • AI

    • AI Assistant & Wizards
    • Agentic Access (MCP)
  • Billing

    • Market & Tariffs
    • How Revenue Is Calculated
    • Accounting & Billing
    • Contracts
    • Service Certificates & Invoices
  • Collaboration

    • Invitations
  • Security

    • Authentication
    • Account Lockout
    • Organization Security Policy
    • Permission System
    • Network Segmentation
    • Cooperation Restrictions
    • Access Audit Logging
    • Activity & Audit Trail
    • Data Isolation
  • Getting Started

    • Onboarding
    • Setup
  • Personal

    • Using the VPN
    • Using the Proxy
    • Two-Factor Authentication
    • Sessions
    • API Tokens
    • Notifications
    • Connect Microsoft Teams
  • Per Park

    • Contacts
    • Network Devices
    • Data Loggers
    • Generic Modbus Reader
    • Components
    • Direct VPN (per Agent)
    • Data Volume
    • History Import
  • Organization

    • Member Permissions
    • Security Policy
    • Cooperations
    • File Storage
    • VPN Services
    • Working with Reports
  • Data Export

    • Metric Export
    • Metric Export API
    • Migrating to the Metric Export
    • Legacy Export API
    • External Report Generation
    • Grafana
    • Grafana Dashboards
    • API Overview
    • MiroxQL Formulas (API)
  • Support

    • Request an Integration
  • Reporting

    • External Report Generator
    • Metric Export for Excel
  • Remote Access
  • Account Security
  • AI in Mirox
  • History Import
  • Reports
  • Data Export
  • English
  • Deutsch
  • Español
  • Français
  • Português
  • Italiano
  • English
  • Information

    • Supported Plants
  • Plant Types

    • Solar Plants
    • Solar Trackers and Park Controllers
    • Transformer Stations
    • Wind Plants
    • Battery Storage
    • Alarm System

Transformer Stations

A transformer station is the plant's MV/LV station: the transformer itself, the medium-voltage ring main unit that connects it to the grid, the low-voltage switchgear the inverters feed into, and the station's own climate and protection supervision. Where a plant's data logger reports its stations, Mirox follows each one as a component of its own. A plant whose loggers report none shows nothing of this.

What a Transformer Station Is in Mirox

Like an inverter, a transformer station is a flat component of the solar plant, discovered automatically from the data logger that reports it — you do not enter stations by hand (though you can add one manually where no logger reports it). A station is identified by its serial number, never by its name: two stations on one plant may well carry the same name, and a renamed station keeps its history.

The station's low-voltage cabinets — the feeders the inverters hang on, lettered A, B, … as the station itself letters them — are not components of their own. Every low-voltage series carries the cabinet as a label, so a graph shows one line per cabinet. Which inverters feed which cabinet is not something the logger knows; it is left to you as an optional note on the station.

Mirox records these series per station:

SeriesScopeWhat it tells you
Active powerper cabinetWhat the cabinet carries now (W); positive = PV power leaving towards the grid, negative = the station drawing from the grid, as at night
Reactive powerper cabinetThe cabinet's reactive power (var)
Power factorper cabinetcos φ of the cabinet
Voltageper cabinet, per phase pairLine voltages on the low-voltage side (V)
Currentper cabinet, per phasePhase currents on the low-voltage side (A)
Exported energyper cabinetThe cabinet's lifetime counter of energy that left towards the grid (Wh)
Imported energyper cabinetThe cabinet's lifetime counter of energy drawn from the grid (Wh)
MV currentper phaseThe transformer's medium-voltage side currents (A)
FrequencystationGrid frequency at the station (Hz)
Oil temperaturestationThe transformer's oil temperature (°C)
Temperature and humidityper roomClimate in each low-voltage cabinet and in the medium-voltage room
Operating statestationThe platform's standard state, the same scale as inverters, trackers and wind turbines
Condition flagsstationThe station's switchgear positions and protection signals packed into one word

The energy counters are the station's own and survive any restart of the monitoring; Mirox never derives a station's energy from its power.

What the operating state means

The station is …Operating state
energised, with at least one low-voltage cabinet closedProducing
de-energised by an open breaker, disconnector or load switch — opened by hand or by remote commandStopped by command
tripped: a protection acted, a breaker opened on a fault, the transformer raised gas, oil level, oil temperature or pressure, or the emergency stop was pressedFault
not delivering a recordno state — a gap, never a value

The condition flags

The condition word has one fixed bit per condition, the same on every plant and every maker. A healthy, energised station reads zero. The conditions: supervision offline; MV breaker open; MV disconnector open; MV earthing switch closed; ring main unit incoming line open; ring main unit outgoing line open (normal on the last station of a ring); low-voltage cabinet A open; low-voltage cabinet B open; a low-voltage breaker tripped on a fault; a transformer protection acted; Buchholz gas; oil temperature high; oil level abnormal; pressure relief valve acted; a door open; smoke; a surge protective device failed; emergency stop pressed; ring main unit insulation gas pressure low; a cabinet's supervision power supply shut down; MV switch control loop disconnected; a smoke sensor fault. How the series are named and decoded for your own dashboards is listed under Metric Collection — Transformer Station Metrics.

What the Pages Show

The Transformer stations page

A solar plant with transformer stations gets a Transformer stations entry in its left-hand navigation. The page holds:

  • a summary row — the number of stations, the low-voltage active power of all of them together, the highest oil temperature and how many stations currently carry a set condition;
  • one graph with a metric toggle — Power, Reactive power, Exported energy, Voltage, Current, MV current, Frequency, Oil temperature, Temperature, Humidity — drawing one line per station, and per cabinet, phase or room where the series carries one, over the time range you pick;
  • the station table: the station's name with its serial, its model and rated power, the active power of each cabinet, the oil temperature, the set conditions, the operating state and when it last reported. The row menu opens the station's details, its edit dialog and, with the permission to create tickets, Create Ticket for that station.

The details show the nameplate as the logger reports it (model, manufacturer, firmware, rated power), the linked datasheet, the live values per cabinet and the serial numbers of the station's supervision units. The edit dialog lets you rename the station, hide it, mark it as needing attention, add a note and pick its datasheet. Hidden stations are left out of this page.

Components page

On a plant with transformer stations, the Components section has a Transformers tab with the same table, searchable, sortable, paged, and with the Show Hidden switch.

Datasheets

Transformer stations have their own entry in the component catalogue under Solar → Transformers: manufacturer and model, the rated apparent power, the medium- and low-voltage side voltages, the vector group, the short-circuit impedance, the no-load and load losses, the cooling class and the number of low-voltage windings, plus the manufacturer's PDF. A station discovered by a logger is linked to its datasheet automatically when the catalogue holds the exact model and manufacturer the logger reports; otherwise you pick the datasheet in the station's edit dialog. The datasheet is shared across every plant that uses the same station type.

Events

When the platform's view of a plant's transformer stations changes — a new station, a changed nameplate — or someone creates, edits or deletes one, the change is recorded under the Components category. Deleting a station breaks its history and is recorded at the Very high level. Events on a station open the Transformer stations page, and a station can be linked to tickets like every other component. Alarms derived from the station's protection signals — a trip, gas, oil or smoke as a judged event with a notification — are the next step and are not raised yet; the condition flags already show every signal live.

Data Collection

Transformer stations reach Mirox through the adapter of the logger that supervises them. The first fielded system is the Huawei Smart Transformer Station read through the Huawei SmartLogger it is connected to: the logger lists the station in its inventory, so a station is discovered the moment the logger is onboarded — nothing to configure. Other makers follow the same model. See the Data Scraper for how the edge agent collects and standardizes plant data.

Related Features

  • Solar Plants — the plant type transformer stations belong to
  • Solar Trackers and Park Controllers — the other optional flat components of a solar plant
  • Events — every event family the platform records
  • Metric Collection — the series names and labels
Prev
Solar Trackers and Park Controllers
Next
Wind Plants
© 2026 Mirox Verwaltungs GmbH. All rights reserved. | Privacy Policy