MiroxMirox
  • Platform

    • Philosophy
    • Platform Overview
    • Platform Resources
    • Availability and Maintenance Windows
    • Releases and Versions
  • Mirox-Cloud

    • Cloud Overview
    • Connected Microservices
  • Mirox-Agent

    • Agent Overview
    • Deployment Options
    • Data Scraper
    • Digital Twin
  • Technical Details

    • Metric Collection
  • Information

    • Supported Plants
  • Plant Types

    • Solar Plants
    • Solar Trackers and Park Controllers
    • Transformer Stations
    • Wind Plants
    • Battery Storage
    • Alarm System
  • Monitoring & Visualization

    • Real-time Monitoring
    • Digital Twin
    • Component States
    • Inverter Status Codes
    • Inverter Events
    • Loss Detection
    • Power Limits & Curtailment
    • Efficiency Detection
    • KPI Dashboard
  • Data Management

    • Events
    • Alarm Levels
    • Tickets
    • Forecasts
    • Reports
    • Metrics
  • Alert Manager

    • Overview
    • Alert Rules
    • Alerts & Notifications
    • Examples
  • Integration & Sharing

    • Cooperations
    • API Tokens
    • VPN
    • VPN Address Conflicts
    • Proxy
  • AI

    • AI Assistant & Wizards
    • Agentic Access (MCP)
  • Billing

    • Market & Tariffs
    • How Revenue Is Calculated
    • Accounting & Billing
    • Contracts
    • Service Certificates & Invoices
  • Collaboration

    • Invitations
  • Security

    • Authentication
    • Account Lockout
    • Organization Security Policy
    • Permission System
    • Network Segmentation
    • Cooperation Restrictions
    • Access Audit Logging
    • Activity & Audit Trail
    • Data Isolation
  • Getting Started

    • Onboarding
    • Setup
  • Personal

    • Using the VPN
    • Using the Proxy
    • Two-Factor Authentication
    • Sessions
    • API Tokens
    • Notifications
    • Connect Microsoft Teams
  • Per Park

    • Contacts
    • Network Devices
    • Data Loggers
    • Generic Modbus Reader
    • Components
    • Direct VPN (per Agent)
    • Data Volume
    • History Import
  • Organization

    • Member Permissions
    • Security Policy
    • Cooperations
    • File Storage
    • VPN Services
    • Working with Reports
  • Data Export

    • Metric Export
    • Metric Export API
    • Migrating to the Metric Export
    • Legacy Export API
    • External Report Generation
    • Grafana
    • Grafana Dashboards
    • API Overview
    • MiroxQL Formulas (API)
  • Support

    • Request an Integration
  • Reporting

    • External Report Generator
    • Metric Export for Excel
  • Remote Access
  • Account Security
  • AI in Mirox
  • History Import
  • Reports
  • Data Export
  • English
  • Deutsch
  • Español
  • Français
  • Português
  • Italiano
  • English
  • Platform

    • Philosophy
    • Platform Overview
    • Platform Resources
    • Availability and Maintenance Windows
    • Releases and Versions
  • Mirox-Cloud

    • Cloud Overview
    • Connected Microservices
  • Mirox-Agent

    • Agent Overview
    • Deployment Options
    • Data Scraper
    • Digital Twin
  • Technical Details

    • Metric Collection
  • Information

    • Supported Plants
  • Plant Types

    • Solar Plants
    • Solar Trackers and Park Controllers
    • Transformer Stations
    • Wind Plants
    • Battery Storage
    • Alarm System
  • Monitoring & Visualization

    • Real-time Monitoring
    • Digital Twin
    • Component States
    • Inverter Status Codes
    • Inverter Events
    • Loss Detection
    • Power Limits & Curtailment
    • Efficiency Detection
    • KPI Dashboard
  • Data Management

    • Events
    • Alarm Levels
    • Tickets
    • Forecasts
    • Reports
    • Metrics
  • Alert Manager

    • Overview
    • Alert Rules
    • Alerts & Notifications
    • Examples
  • Integration & Sharing

    • Cooperations
    • API Tokens
    • VPN
    • VPN Address Conflicts
    • Proxy
  • AI

    • AI Assistant & Wizards
    • Agentic Access (MCP)
  • Billing

    • Market & Tariffs
    • How Revenue Is Calculated
    • Accounting & Billing
    • Contracts
    • Service Certificates & Invoices
  • Collaboration

    • Invitations
  • Security

    • Authentication
    • Account Lockout
    • Organization Security Policy
    • Permission System
    • Network Segmentation
    • Cooperation Restrictions
    • Access Audit Logging
    • Activity & Audit Trail
    • Data Isolation
  • Getting Started

    • Onboarding
    • Setup
  • Personal

    • Using the VPN
    • Using the Proxy
    • Two-Factor Authentication
    • Sessions
    • API Tokens
    • Notifications
    • Connect Microsoft Teams
  • Per Park

    • Contacts
    • Network Devices
    • Data Loggers
    • Generic Modbus Reader
    • Components
    • Direct VPN (per Agent)
    • Data Volume
    • History Import
  • Organization

    • Member Permissions
    • Security Policy
    • Cooperations
    • File Storage
    • VPN Services
    • Working with Reports
  • Data Export

    • Metric Export
    • Metric Export API
    • Migrating to the Metric Export
    • Legacy Export API
    • External Report Generation
    • Grafana
    • Grafana Dashboards
    • API Overview
    • MiroxQL Formulas (API)
  • Support

    • Request an Integration
  • Reporting

    • External Report Generator
    • Metric Export for Excel
  • Remote Access
  • Account Security
  • AI in Mirox
  • History Import
  • Reports
  • Data Export
  • English
  • Deutsch
  • Español
  • Français
  • Português
  • Italiano
  • English
  • Monitoring & Visualization

    • Real-Time Monitoring
    • Digital Twin
    • Component States
    • Inverter Status Codes
    • Inverter Events
    • Loss Detection
    • Power Limits and Curtailment
    • Efficiency Detection (PRRC)
    • Local Network Inspector
    • Access Monitoring
    • KPI Dashboard
    • Graph Visualization
  • Data Management

    • Events
    • Alarm Levels and Notifiable Events
    • Tickets
    • Forecasts
    • Reports
    • Metrics
  • Alert Manager

    • Alert Manager
    • Alert Rules
    • Alerts & Notifications
    • Examples
  • Integration & Sharing

    • Cooperations
    • API Tokens
    • VPN
    • VPN: Address Conflicts
    • Proxy (Web Access to Plant Devices)
  • AI

    • AI Assistant & Wizards
    • Agentic Access (MCP)
  • Billing

    • Market & Tariffs
    • How Revenue Is Calculated
    • Accounting & Billing
    • Contracts
    • Service Certificates & Invoices
  • Collaboration

    • Invitations
  • Security

    • Authentication
    • Account Temporarily Locked
    • Organization Security Policy
    • Permission System
    • Network Segmentation
    • Cooperation Permission Restrictions
    • Access Audit Logging
    • Activity & Audit Trail
    • Data Isolation

Events

Events are the machine-detected signals your plants raise on their own — a grid shutdown, an overproduction cap, a logger losing contact with its source. They give you an objective, time-stamped record of what happened, so you can react quickly and prove later what the platform observed and when.

Events Concept

An event is automatically created when the platform recognizes a noteworthy condition at a plant. Most events come from the Digital Twin and the monitoring agents watching each plant; others are emitted as a side effect of configuration changes (for example, when a data logger is added or paused). You can also record an event yourself for something you observed on site.

Events are deliberately lightweight: each one captures what the platform detected, where, when, and how serious it is. The human side of the story — triage notes, who is working on it, what was done to fix it — lives in Tickets, not on the event itself.

Events vs. Tickets

An event is a detected signal (often automatic). A ticket is the human follow-up: investigation, assignment, comments, and resolution. You link the two together so the detected signal and the work to resolve it stay connected. Free-text title and description fields on events are being retired in favour of tickets — treat the event as the trigger and the ticket as the workspace.

Event Types

Each event carries a type that tells you what was detected. The types fall into a few families:

Production and grid

  • A curtailment by the grid operator or the direct marketer is recorded as Detected Curtailment (see Curtailment and settlement below).
  • Overproduction: the plant exceeded its expected or permitted production level.

Component health — raised by the plant's Component Health Watchdog. Each type is named for the component it sits on, so an inverter, a combiner box and a string carry their own version of the same finding. For inverters, Inverter Events explains every one of these in detail — what opens it, what confirms it, and how it closes.

Production — exactly one of these stands on a component at a time:

  • Inverter production outage: confirmed zero production under conditions that warrant production.
  • Inverter measurement conflict: the inverter is producing, but its own reading is wrong — a data fault to investigate, never counted as lost production.
  • Inverter not communicating: the inverter stopped reporting — its production is unknown, deliberately not counted as loss.
  • Inverter reduced output: the inverter is producing, but far below its modelled expectation.

And one park-level roll-up, which stands on top of the component events rather than instead of them:

  • Component outage summary: the single high-priority park summary that lists every currently-down unit — inverters, combiner boxes, wind turbines and battery units alike, so a hybrid site still has one summary — this roll-up carries the operator alarm.

Service findings — an inverter that is producing at full output while something wears out. Each opens as an Observing: … row first and becomes a confirmed finding once the evidence holds:

  • Inverter elevated temperature: it runs measurably hotter than comparable units on the same logger under the same load.
  • Inverter insulation weakening: its settled morning insulation reading keeps falling below its peers'.
  • Inverter phase imbalance: the three AC phases no longer carry the same current.
  • Inverter efficiency declining: the DC-to-AC conversion loss grows month over month beyond what load and temperature explain.

Device state — what the machine says about its own condition, one event per mode:

  • Inverter device fault: the inverter reports a fault of its own, in a function the platform has no measurement for — hardware, firmware, licence, configuration, an emergency stop, a DC string or metering. A service item, not a production loss.
  • Logger cannot reach inverter: the logger says it cannot reach the machine while no readings of ours arrive from it either. A quiet background record — it notifies nobody and puts no state on the inverter; after an hour of daylight it is handed over into a no-communication event.
  • Inverter safety alarm: an arc fault or a residual-current condition the device reports — opened on a single live report, day or night.
  • Inverter protective stop: a protection mechanism tripped the machine; it may need a manual restart on site.
  • Inverter stopped by command: it was switched off deliberately, by a person or a remote instruction.
  • Inverter self-derating: it is producing but throttling itself to protect itself, most often against heat.

Device-reported mirror — the manufacturer's own active alarm list, copied as it was sent and never judged:

  • Inverter fault reported by device / Inverter warning reported by device (and the battery, wind-turbine, solar-tracker and park-controller equivalents): one record per code, opened when the device raises it and closed when the device withdraws it. They are detail behind the judged events — they never notify on their own. They are filed under the Vendor alarms category in the event list, whatever the plant type.

Wind turbines — judged from each turbine's 10-minute data; see Alarm Levels — Wind turbines:

  • Turbine stopped by fault: the turbine reports a fault or protection stop. Joins the component outage summary after two consecutive rows.
  • Turbine not communicating: the turbine's data stopped while the other turbines of the site still deliver.
  • Turbine safety alarm: fire, smoke or an arc in the converter or switchgear — Critical, notified at once.

A remote pause, bat, shadow-flicker, ice or noise curtailment, a stop ordered by the marketer or the grid operator, a keyboard pause or a service stop is status, not an event.

Battery storage — judged per power converter (PCS) and battery container on every site with battery hardware, including solar plants with storage; see Alarm Levels — Battery storage:

  • Battery unit stopped by fault: the unit's status word reports a fault for five minutes. Joins the component outage summary after 15 minutes.
  • Battery unit not communicating: one unit's data stopped while its data source keeps delivering.
  • Battery device fault: the unit reports a fault of its own but keeps operating — a service item, not a stop.
  • Battery unit not following dispatch: the unit was ordered to charge or discharge and for 15 minutes did not move in that direction, or moved against it, while the storage as a whole did not follow either. Only the direction counts, never how much. Joins the component outage summary 15 minutes later.
  • Battery safety alarm: a fire alarm, smoke or gas detection, thermal runaway, a released fire suppression or an arc — Critical, notified at once.

Battery events carry the same categories in the event list as those of the other plant types — faults, stops and safety alarms Production, a unit that stops communicating Availability, the battery's own device-reported alarms Vendor alarms — and notify through the Production row of your notification settings. Earlier records may still show the Battery category.

Solar trackers and park controllers — a tracker row judged from the record its field refreshes about every five minutes, and the optional park controller of a tracker field or a battery plant judged from its one-minute reads; see Alarm Levels — Solar trackers and park controllers:

  • Tracker stopped by fault: the row's error word stays set for two refreshes, about 10 minutes.
  • Tracker not communicating: no record for three refreshes while the field keeps refreshing.
  • Tracker misaligned (Low): at least 10° off its setpoint for about 15 minutes while it is tracking and the field controller holds no stow, override or cleaning.
  • Tracker safety alarm: a danger class reported by the row — Critical, notified at once.
  • Park controller fault: the controller reports the plant in fault for two consecutive reads — Critical, notified on its own.
  • Park controller not communicating: no reading for 15 minutes.
  • Park controller safety alarm: a fire alarm, smoke or gas detection or a released fire suppression on the plant level — Critical, notified at once.
  • Park controller stopped by command (Low): standby, night mode, a stow, an override or a cleaning run — recorded as the explanation, never notified.

Trackers never join the component outage summary. Changes to a plant's trackers and park controllers — discovered or edited — are recorded under the Components category.

Alarm system — the plant's alarm signals: signals your organisation defined with the generic Modbus reader, and the fixed contacts of existing WAGO installations (the intrusion alarm panel and the communication cabinet); see Alarm System:

  • Alarm raised (Critical), Alarm panel fault, UPS alarm and Main switch off (High), UPS on battery and Heating breaker tripped (Normal): each opens while its contact is asserted and closes when it returns to normal. An open gate or door is recorded as a signal only.
  • Operator-defined signal (level set per signal): a contact, a status bit or a measured value against a limit, defined on a Modbus device. It opens while its condition holds and closes when it returns to normal; a signal without a condition is recorded only.
  • Alarm signals not readable (High): the device a reader polls stopped answering — the signals are then unknown, not normal.

Sensor health — a staged chain, so a healthy sensor is never condemned on weak evidence:

  • Sensor Investigation: an irradiance channel stopped delivering usable signal — under observation.
  • Sensor Defect: the fault is corroborated by independent evidence — replace the sensor.
  • Sensor Soiling: the sensor dome is dirty or snow-covered — clean it; escalates to a defect if it does not recover.

String investigations — the same staged approach for strings:

  • String Investigation: a string shows unexplained zeros under conditions that warrant production — under observation.
  • String Outage / String Defect: the investigation was confirmed — a dead string, or one producing far below its siblings without recovering.
  • String Shading: the string's zeros recur along the sun's path — recorded quietly as shading, not a defect.

Connection and availability — one alarm at the layer where the root cause sits:

  • VPN Offline: the monitoring tunnel to the plant is down.
  • Park Network Offline: the plant's local network is unreachable.
  • Network Device Offline: a single monitored network device stopped answering.
  • Network Device Mass Outage: a large share of the plant's devices went offline together.

Curtailment and settlement — see Curtailment Settlement for the full explanation:

  • Detected Curtailment: the live record of each curtailment episode, with its real start, end and limit.
  • Settlement Records: the bookkeeping behind compensation — a settlement event per curtailment measure with the legal method and figures, a monthly value per plant, and revision events for later official price corrections. They appear under the Curtailment analysis category in the event list.

Energy integrity

  • Energy Counter Stalled: a device's lifetime energy register stopped advancing while it keeps producing — its own record of production needs repair.
  • Feed-in Energy Estimated: part of the plant's feed-in series is temporarily estimated from power readings.

Data acquisition and configuration

  • Source Availability: a data source became unreachable or recovered (data acquisition gap).
  • Logger Lifecycle: a data logger was created, updated, paused, resumed, deleted, or had its credentials changed.
  • User Created: an event you recorded manually for an observed condition.

Logger-level events

Some problems sit in a data logger rather than in the machines behind it. Mirox then records the logger's problem once and links the units to it:

  • Source availability: a data logger stopped delivering — it does not answer, refuses access (login or password) or answers without sending any data. This is the one event that notifies you about a dead logger.
  • Inverter / Combiner box / Battery unit / Turbine unreachable (logger offline) (Low): one record per unit behind a logger whose network connection is down. Its production is unknown, not zero. It never notifies, is never counted on its own, cannot be closed by hand, and closes together with the logger's event — or hands over to the unit's own outage or no-communication event if one opens.
  • Logger measurement issue (Normal): two or more components measured by the same logger report values that contradict their own production — measurement conflicts, an energy counter that disagrees with power, or a stalled counter. It names its members and closes when none of them is left.
  • Inverter energy counter disagrees with power / Battery converter energy counter disagrees with power (Normal): the device's own energy counter and its measured power tell different stories on several days. Production is credited from power; the counter needs checking.

On the Monitor such a logger is one row, with its units folded under it.

Event Priority

Every event carries one of six levels — Critical, Very High, High, Normal, Low and Very Low. The level is set by the platform per event type and is the same on every plant — with one exception, operator-defined alarm signals, whose level the plant's technical operator sets per signal: Critical means possible physical danger, High a site situation that costs production or leaves you blind, Normal a single unit's state. Which events open at which level, how fast they are detected and which of them can notify you is listed in Alarm Levels; you choose the minimum level per category on your notification settings.

Event Status

Events move through a short, clear lifecycle:

  • Detected: the event has just been raised and not yet reviewed.
  • Acknowledged: someone has seen the event and accepted it for follow-up.
  • Closed: the underlying condition is resolved. Many events close automatically — for example when a curtailed source reconnects, a shutdown ends, or overproduction subsides — while others are closed manually once the work is done.

Closed events can be reopened if the condition returns, so a recurring problem keeps its history together.

Linking and Follow-Up

Events do not stand alone. You can connect each event to the parts of the plant it concerns and to the work needed to resolve it:

  • Component Links: attach an event to the specific components it affects (a logger, inverter, GAK, string, feed-in meter, or sensor), and search the plant's components to find the right one.
  • Ticket Links: reference an event from a ticket so investigation, assignment, comments, and resolution are tracked in one place.
  • Notification Tracking: each event records which users were notified and who has seen it.

Part of. An event that belongs to a larger one shows Part of: … in its details: a unit behind an offline logger links the logger's event, a member of a logger measurement issue links that issue, and a combiner-box or string event links the standing event of its inverter, which carries the device's own codes. Click it to open that event.

Use tickets for the work

When an event needs investigation or a fix, open a ticket and link the event to it. The ticket carries the assignee, comments, mentions, and a full activity history; the event stays as the objective record of what was detected.

Finding and Reviewing Events

Events are retained as a long-term history so you can both react in the moment and analyze trends later:

  • List and Filter: browse events across the plants you can access, filtered by plant, portfolio, type, status, or priority, and sorted to surface the newest or most urgent first.
  • Counts: at-a-glance counters summarize how many events are open and how they break down, feeding the KPI Dashboard.
  • Detail View: open any event to see its full context, linked components, linked tickets, and notification history.
  • Historical Record: closed events stay available for audits, warranty claims, and identifying recurring patterns over time.

Access and Permissions

Events are a plant sub-resource, so access follows your role on the parent plant — not a separate setting. Anyone who can view a plant can see its events. Beyond that:

  • Technical roles — Operators and Technical Managers get full event handling: acknowledge, create, close, and delete.
  • Asset Manager (Commercial) can create and acknowledge events for commercial oversight, but cannot delete them.
  • Viewers have read-only access.

Cooperators who hold the required job role on a shared plant are included on the same terms. See the Permission System for the full role model.

Related Features

  • Tickets — the human follow-up workspace where events are triaged and resolved
  • Alarm Levels — every event that can notify, its level, timing and examples
  • Inverter Events — every component-health event an inverter can carry, in detail
  • Digital Twin — the analysis engine that detects most events
  • Loss Detection — quantifies the production lost during shutdowns
  • KPI Dashboard — surfaces event counts alongside performance metrics
  • Reports — incorporates event and shutdown-loss data into periodic documentation
Next
Alarm Levels and Notifiable Events